Productoverzicht
Productdetails
Gegevens downloaden
gerelateerde producten
Neem contact met ons op
MODEL | LRS-350-12 | LRS-350-15 | LRS-350-24 | LRS-350-36 | LRS-350-48 | |
UITGANG | GELIJKSTROOMSPANNING | 12V | 15V | 24V | 36V | 48V |
NOMINALE STROOM | 29A | 23,2A | 14,6A | 9,7A | 7,3A | |
HUIDIG AANBOD | 0 ~ 29A | 0 ~ 23,2A | 0 ~ 14,6A | 0 ~ 9,7A | 0 ~ 7,3A | |
NOMINAAL VERMOGEN | 348W | 348W | 350,4 W | 349,2 W | 350,4 W | |
RIMPEL & GELUID (max.) Opmerking.2 | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
SPANNING ADJ.BEREIK | 10,2~13,8V | 13,5~18V | 21,6~28,8V | 32,4~39,6V | 43,2~52,8V | |
SPANNINGTOLERANTIE Opmerking.3 | ±1,5% | ±1,0% | ±1,0% | ±1,0% | ±1,0% | |
LIJNREGELING Noot.4 | ±0,5% | ±0,5% | ±0,5% | ±0,5% | ±0,5% | |
BELASTINGREGELING Opmerking.5 | ±1,0% | ±0,5% | ±0,5% | ±0,5% | ±0,5% | |
OPSTELLING, OPKOMSTTIJD | 1300 ms, 50 ms/230VAC 1300 ms, 50 ms/115VAC bij volledige belasting | |||||
HOUDTIJD (typ.) | 16 ms/230 VAC 12 ms/115 VAC bij volledige belasting | |||||
INVOER | SPANNINGSBEREIK | 90 ~ 132VAC / 180 ~ 264VAC via schakelaar 240 ~ 370VDC (schakelaar op 230VAC) | ||||
FREQUENTIEBEREIK | 47 ~ 63 Hz | |||||
EFFICIËNTIE (typ.) | 85% | 86% | 88% | 88,50% | 89% | |
AC-STROOM (typ.) | 6,8A/115VAC 3,4A/230VAC | |||||
INSCHAKELINGSSTROOM (typ.) | 60A/115VAC 60A/230VAC | |||||
LEKSTROOM | <2mA / 240VAC | |||||
BESCHERMING | OVERBELASTEN | 110 ~ 140% nominaal uitgangsvermogen | ||||
Beveiligingstype: Hikmodus, herstelt automatisch nadat de foutconditie is opgeheven | ||||||
FUNCTIE | VENTILATOR AAN/UIT-BEDIENING | RTH3三50℃ VENTILATOR AAN, ≦40℃ VENTILATOR UIT | ||||
OMGEVING | WERKTEMP. | -20 ~ +70℃ (zie "Derating Curve") | ||||
WERKVOCHT | 20 ~ 90% RH niet-condenserend | |||||
OPSLAGTEMP., VOCHTIGHEID | -40 ~ +85℃, 10 ~ 95% relatieve luchtvochtigheid | |||||
TEMP.COËFFICIËNT | ±0,03%/℃ (0 ~ 50℃) | |||||
TRILLING | 10 ~ 500 Hz, 5G 10 min./1 cyclus, 60 min.elk langs de X-, Y- en Z-assen | |||||
VEILIGHEID & EMC | NORMEN | EN60950 - 1 | ||||
Bestand tegen spanning | I/PO/P:1,5KVAC I/P-FG:1,5KVAC O/P-FG:0,5KVAC | |||||
ISOLATIEWEERSTAND | I/PO/P, I/P-FG, O/P-FG: 100M Ohm/500VDC / 25℃/70% RH | |||||
ANDEREN | MTBF | 327,9K uur min.MIL-HDBK-217F (25℃) | ||||
DIMENSIE | 215*115*30mm (L*B*H) | |||||
GEWICHT | 0,76 kg |